4.2 History Record
Click the notice 3 in picture 1.6.1.This button indicates Axis Alarms Information, enter into the page of Driver information. As shown in the below picture 1.6.2:
These information of alarms in the above picture only can be used in Sigmatek drivers. The specific alarms' reasons and resolvent are listed in the below table:
| Alarms Name | Hand controller display | Reasons and resolvents | Breakdown reason and elimination methods |
|---|---|---|---|
| Phase lack alarm | SDD_OnePhase | Motor starts without three phase power supply |
|
| Dynamic voltage alarm | SDD_MainError | The main power supply is not normal when motor starts. |
|
| Overvoltage(Regenerative resistor deficiency) | SDD_DCOver | DC bus voltage is higher than safety value. This value is depended on the parameter G-VMAINS (driver parameter) | Motor produce the back EMF in running and the EMF will increase with speed of revolution increases. This problem occurs when speed is too fast. Motor can not run normally if the power supply voltage is too slow. Check Whether three phase power supply meets the requirement. For example system of 400V connects with the power of 200V. |
| Low voltage | SDD_DCUnder | DC bus voltage is lower than set value of parameter when motor starts. | DC bus voltage is lower than the safety scope. There are 3 notices: firstly, whether three phase power supply is normal; secondly,slow down the speed when the back EMF is too high;thirdly, the overall power is not enough, the ability of output is not enough as a result of the too big motor. |
| Brake error | SDD_BrakeError | Brakek closed is tested abnormal when close the brake, such as lines of brake is short, temperature exceeds the limit and so on. |
|
| Brake with error | SDD_BrakeSwitchError | The connections of brake is abnormal, short or broken when open the brake. |
|
| Motor overheating | SDD_MotorOverTemp | Resistance of motor temperature transducer I-TEMPM is higher than the maximum resistance M-RTEMP | Estimate the temperature with hands. There are problems in motor lines, encoder line or interior resistance if the temperature of motor's surface does nor reach the overheated degree. |
| Drive bad heat | SDD_AmbientOverTemp | Interior temperature I-TEMPE exceeds the set value G-MTEMPE | Drivers abstract heat bad and improve the airiness. |
| Drive the radiator overheated | SDD_HeatSinkOverTemp | The thermal temperature I-TEMPK exceeds the set value G-MTEMPK | Fasten the heat dissipator to the baseboard to exchange abstracting heat. |
| Encoder feedback abnormally | SDD_FeedbackError |
| |
| Abnormal communication | SDD_CommunicationError | When the motor running direction and I-NFILT in opposite directions, if the acceleration of mor than 300 upm/s or I-NFILT>NMAX/4, Alarm | |
| Motor speed exceeds limit | SDD_OverSpeed | Motor speed exceeds the maximum speed of driver. | This problem may occur if encoder is abnormal with normal motor speed. |
| Position deviation is too large | SDD_PEMax | Alarm will be given out when the actual position deviation exceeds the maximum | Try again after slowing down the speed. It is possible that the mechanical properties were changed. |
| Command acceleration exceeds limit | SDD_PCmdError | Alarms will be given out when speed produced by exceeds 10000/minute | |
| The main control communication abnormalities | SDD_HostComError | PC control failure | |
| Driver interior error E2 | SDD_DriveError_E2 | Drive internal circuit breaker. The operation timed out, or analog-to-digital convert is abnormal |
|
| Driver interior error E1 | SDD_DriveError_E1 | Driver motherboard, as problems occurs in the internal storage | Change the driver |
| Safety input abnormally | SDD_EnableLockedError | Safety signals do not input, or safety device is abnormal | Check safety signal input of VAC |
| Regenerative resistor deficiency | SDD_MaxRegenPower | Alarms will be given out when the regenerative resistor I-PBAL>The maximum regeneration resistor G-MBAL |
|
| Power supply 24V of brake is abnormal | SDD_Brake24VError | 24V power supply or brake is bad. Signal of brake open loses. | |
| Motor overload | SDD_12TError | Alarms will be given out when load rate I-12T≥100% at the start of motor. | This problem occurs when encoder is abnormal, also when motor oscillate frequently. |
| Motor temperature alarm | SDD_MotorTempWarn | Alarms will be given out when actual temperature I-TEMPM> (maximum temperature M-RTEMP*motor alarm temperature A-TEMPMV/100) | Check the connections in the temperature sensor line of motor encoder lines. Touch motor's surface with hands to estimate whether there exists problems of overheat Change a motor if everything is normal. |
| Motor temperature alarm | SDD_MotorTempWarn | Alarms will be given out when actual temperature I-TEMPM> (maximum temperature M-RTEMP*motor alarm temperature A-TEMPMW/100) | Check the connections in the temperature sensor line of motor encoder lines. Thouch motor's surface with hands to estimate whether there exists problems of overheat. Changes a motor if everything is normal. |
| Motor parameters do not match | SDD_MotorObjectError | Set parameter is not matching with motor. it is only adapted with using End at or Hiperface encoder. | Load the wrong document of parameter. It need to update program. |
| Resolution ratio of encoder do not match Motor information do not match | SDD_MutiPosError | The type of encoder is different from set type, or the precision of encoder is different from set one. |
|
| Excess load | SDD_MaxSumPowerLimit | The maximum output power limitation |
Record of manipulation. As shown in the below picture 1.6.4:
1.The specific data classification of Detailed record. Include record types (alarm/manipulation instruction), manipulation No./Alarms No., Count, the last record of arrived, the last record of gone and specific description about alarms/manipulation. Drag the scroll bar at the bottom of this picture to right hand. As shown in the below picture 1.6.5: