| Parameter No. | Title | Range | Default | Unit | Turning on of power supply | Related Control Mode | Detail page | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Class | No. | A,B-frame | C-frame | D,E,F-frame | P | S | T | F | |||||
| 3 | 00 | Speed setup, Internal/External switching | 0 to 3 | 0 | — | ○ | 4-31 | ||||||
| 3 | 01 | Speed command rotational direction selection | 0 to 1 | 0 | — | ○ | |||||||
| 3 | 02 | Input gain of speed command | 10 to 2000 | 500 | (r/min)/V | ○ | ○ | 4-32 | |||||
| 3 | 03 | Reversal of speed command input | 0 to 1 | 1 | — | ○ | |||||||
| 3 | 04 | 1st speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | 4-33 | ||||||
| 3 | 05 | 2nd speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 06 | 3rd speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 07 | 4th speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 08 | 5th speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 09 | 6th speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 10 | 7th speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 11 | 8th speed of speed setup | -20000 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 12 | Aacceleration time setup | 0 to 10000 | 0 | ms/(1000 r/min) | ○ | |||||||
| 3 | 13 | Deceleration time setup | 0 to 10000 | 0 | ms/(1000 r/min) | ○ | |||||||
| 3 | 14 | Sigmoid acceleration/deceleration time setup | 0 to 1000 | 0 | ms | ○ | 4-34 | ||||||
| 3 | 15 | Speed zero-clamp function selection | 0 to 3 | 0 | r/min | ○ | |||||||
| 3 | 16 | Speed zero clamp level | 10 to 20000 | 30 | r/min | ○ | ○ | ||||||
| 3 | 17 | Selection of torque command | 0 to 2 | 0 | — | ○ | 4-35 | ||||||
| 3 | 18 | Torque command direction selection | 0 to 1 | 0 | — | ○ | |||||||
| 3 | 19 | Input gain of torque command | 10 to 1000 | 30 | 0.1V/100%* | ○ | |||||||
| 3 | 20 | Input reversal of torque command | 0 to 1 | 0 | — | ○ | 4-36 | ||||||
| 3 | 21 | Speed limit value 1 | 0 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 22 | Speed limit value 2 | 0 to 20000 | 0 | r/min | ○ | |||||||
| 3 | 23 | External scale selection | 0 to 6 | 0 | — | ○ | ○ | 4-37 | |||||
| 3 | 24 | Numberator of external scale division | 0 to 223 | 0 | — | ○ | ○ | ||||||
| 3 | 25 | Denominator of external scale division | 1 to 223 | 10000 | — | ○ | ○ | ||||||
| 3 | 26 | Reversal of direction of external scale | 0 to 3 | 0 | — | ○ | ○ | 4-38 | |||||
| 3 | 27 | External scale Z phase disconnection detection disable | 0 to 1 | 0 | — | ○ | ○ | ||||||
| 3 | 28 | Hybrid deviation excess setup | 1 to 227 | 16000 | Command unit | ○ | ○ | ||||||
| 3 | 29 | Hybrid deviation clear setup | 0 to 100 | 0 | Revolution | ○ | ○ | ||||||
Caution → Tye symbol "*" attached to "Unit". indicates that the digits of setting unit will change if the parameter is set by using the setup support software PANATERM.
Note → Parameter describes of this page is P.4-6 to P.4-85.