[Class 2] Damping control
Parameter No. Title Range Deafault Unit Tuming on of power supply Related Control Mode Detail page
Class No. A,B-frame C-frame D,E,F-frame P S T F
2 00 Adaptive filter mode setup 0 to 6 0 4-23
2 01 1st notch frequency 50 to 5000 5000 Hz
2 02 1st notch width selection 0 to 20 2
2 03 1stnotch depth selection 0 to 99 0
2 04 2nd notch width frequency 50 to 5000 5000 Hz
2 05 2nd notch width selection 0 to 20 2 4-24
2 06 2nd notch deptch selection 0 to 99 0
2 07 3rd notch frequency 50 to 5000 5000 Hz
2 08 3rd notch width selection 0 to 20 2
2 09 3rd notch depth selection 0 to 99 0
2 10 4th notch frequency 50 to 5000 5000 Hz
2 11 4th notch width selection 0 to 20 2
2 12 4th notch depth selection 0 to 99 0 4-25
2 13 Selection of damping filter switching 0 to 6 0
2 14 1st damping frequency 0 to 3000 0 0.1Hz* 4-26
2 15 1st damping filter setup 0 to 1500 0 0.1Hz*
2 16 2nd damping frequency 0 to 3000 0 0.1Hz*
2 17 2nd damping filter setup 0 to 1500 0 0.1Hz*
2 18 3rd damping frequency 0 to 3000 0 0.1Hz*
2 19 3rd damping filter setup 0 to 1500 0 0.1Hz*
2 20 4th damping frequency 0 to 3000 0 0.1Hz*
2 22 4th damping filter setup 0 to 1500 0 0.1Hz*
2 22 Positional command smoothing filter 0 to 10000 92 139 0.1 ms* 4-27
2 23 Positional command FIR filter 0 to 10000 10 0.1 ms* 4-28
2 24 5th notch frequency 50 to 5000 5000 Hz 4-29
2 25 5th notch width selection 0 to 20 2
2 26 5th notch depth selection 0 to 99 0
2 27 1st damping width setting 0 to 1000 0
2 28 2nd damping width setting 0 to 1000 0
2 29 3rd damping width setting 0 to 1000 0
2 30 4th damping width setting 0 to 1000 0
2 31 For manufacturer's use 0 4-30
2 32 For manufacturer's use 0
2 33 For manufacturer's use 0
2 34 For manufacturer's use 0
2 35 For manufacturer's use 0
2 36 For manufacturer's use 0
2 37 For manufacturer's use 0

Caution → The symbol "*" attached to "Unit". indicates that the digits of setting unit will change if the parameter is set by using the setup support software PANATERM.
Note → Parameter describes of this page is P.4-16 to P.4-22. P.4-23 to P.4-24. P.4-85.


Turn-key IML Solutions

WhatsApp

WeChat


Send Us An Inquiry Now
Submit

This unit of the websit is a platform for the Chinese manufacturer of injection molding machinery and technology for the global buyer to have a fast sourching reference of the injection molding machineries for their project. If you have any inquiry or have anything new in injection molding to share please feel free to contact the Blogger to start a win-win cooperation.